-A A +A
Type: 
Journal
Description: 
The Silicon Carbide detector (SiC) is an object of research as an alternative to diamond detectors for fast neutron detection and spectrometry where harsh environments are an issue, like in Tokamaks. Since future breeding blankets mock-ups will feature temperatures up to 550 °C, diamond detectors were characterized in the past, finding limitations in their functionality at high temperatures. This paper expands on the previous work by proving the detection of fast neutrons with good detection parameters of a 250 μm-thick 4 H-SiC detector prototype at temperatures up to 250 °C, highlighting the detector's excellent resilience to temperature. The experiment is conducted with instrumentation similar to the one used in the past with diamond detectors, using as source of irradiation the Frascati Neutron Generator (FNG) in ENEA, which is accelerator driven neutron source based on deuterium-tritium (DT) fusion reaction.
Publisher: 
North-Holland
Publication date: 
1 Jul 2024
Authors: 

Matteo Hakeem Kushoro, Maurizio Angelone, Daniele Bozzi, Stephanie Cancelli, Andrea Dal Molin, Erik Gallo, Giuseppe Gorini, Francesco La Via, Miriam Parisi, Enrico Perelli Cippo, Oscar Putignano, Marco Tardocchi, Marica Rebai

Biblio References: 
Volume: 204 Pages: 114486
Origin: 
Fusion Engineering and Design