-A A +A
Type: 
Journal
Description: 
Silicon-Carbide detectors are extensively employed as diagnostic devices in laser-generated plasma, allowing the simultaneous detection of photons, electrons and ions, when used in time-of-flight configuration. The plasma generated by high intensity laser (1016 W/cm2) producing high energy ions was characterized by SiC detector with a continuous front-electrode, and a very thick active depth, while SiC detector with an Interdigit front-electrode was used to measure the low energy ions of plasma generated by low intensity laser (1010 W/cm2). Information about ion energy, number of charge states, plasma temperature can be accurately obtained. However, laser exposure induces the formation of surface and bulk defects whose concentration increases with increasing the time to plasma exposure. The surface defects consist of clusters with a main size of the order of some microns and they modify the diode …
Publisher: 
EDP Sciences
Publication date: 
1 Jan 2018
Authors: 

Antonella Sciuto, Lorenzo Torrisi, Antonino Cannavò, Massimo Mazzillo, Lucia Calcagno

Biblio References: 
Volume: 167 Pages: 03005
Origin: 
EPJ Web of Conferences